Universal vibration analyzer with simple operation via touch screen
Frequency analysis and overall value measurements with long-term plot (scope of delivery)
Optionally licensed functions:
Route-based measurements on machines
Rolling bearing diagnosis
Balancing in one or two planes
Hand-arm and whole-body vibration measurement; ride comfort evaluation
Run-up and coast-down analysis; resonance finding
Vibration measurements on very sensitive equipment (VC/Nano)
Technische Daten
Technical data
Channel number | 9 |
Measuring range acceleration | 0,0001 .. 100 000 m/s² |
Measuring range velocity | 0,0001 .. 100 000 mm/s |
Measuring range displacement | 0,000 01 .. 100 mm |
Frequency range acceleration | 0,4 .. 24 000 Hz, div. Filter |
Frequency range velocity | 2 .. 2000 Hz, div. Filter |
Frequency range displacement | 2 .. 300 Hz, div. Filter |
RMS | yes |
Peak value | Hold peak, Peak, Peak-to-Peak |
Crest factor | yes |
Vector sum (X/Y/Z) | yes |
Frequency analysis (FFT) | 1024 .. 65 536 points |
Main frequency | yes |
Measurement memory | Bitmap, CSV, SD card, WAVE |
Zubehör für dieses Produkt
Accessories for this Product
Ähnliche Produkte
Related products
VM100A
-
Channel number 9
Measuring range acceleration 0,0001 .. 100 000 m/s²
Measuring range velocity 0,0001 .. 100 000 mm/s
Measuring range displacement 0,000 01 .. 100 mm
Frequency range acceleration 0,4 .. 24 000 Hz, div. Filter
Frequency range velocity 2 .. 2000 Hz, div. Filter
Frequency range displacement 2 .. 300 Hz, div. Filter
RMS yes
Peak value Hold peak, Peak, Peak-to-Peak
Crest factor yes
Vector sum (X/Y/Z) yes
Frequency analysis (FFT) 1024 .. 65 536 points
Main frequency yes
Measurement memory Bitmap, CSV, SD card, WAVE
-
VM100B
Channel number 3
Measuring range acceleration 0,0001 .. 100 000 m/s²
Measuring range velocity 0,0001 .. 100 000 mm/s
Measuring range displacement 0,000 01 .. 100 mm
Frequency range acceleration 0,4 .. 24 000 Hz, div. Filter
Frequency range velocity 2 .. 2000 Hz, div. Filter
Frequency range displacement 2 .. 300 Hz, div. Filter
RMS yes
Peak value Hold peak, Peak, Peak-to-Peak
Crest factor yes
Vector sum (X/Y/Z) yes
Frequency analysis (FFT) 1024 .. 65 536 points
Main frequency yes
Measurement memory Bitmap, CSV, SD card, WAVE
MehrMore
Signal Conditioners
Vibration Meters
Vibration Calibrators
Human Vibration
Building Vibration
PC Data Acquisition
Cables and accessories